Skip to main content
Home / Diagnostics / Test Library
2002 LS1 · TEST LIBRARY

Diagnostic Test Library

Only tests supported by the diagnostic material currently supplied for the 2002 LS1 are published here.

Open the exact test from a diagnostic tree, perform it once, then return to the branch with a real pass/fail result.

Resume Saved Diagnosis →

Full test procedures live here so a diagnostic path can stay readable without stripping out the details needed to perform the test.

Tools used in these tests

See the diagnostic tools already linked from FPV exact-test procedures, with direct routes back to the tests that use them.

Open Diagnostic Tool Bench →

Tests connected to current diagnostic paths

These exact tests are currently linked into the supported FPV diagnostic flows.

Best way to use this: start from the symptom in Diagnostics. The tree will send you here only when a measurement is needed.
These are not generic automotive how-tos. Each test keeps its 2002 application, setup, measured result and stop point. If the supplied information stops before a pin-level circuit test, FPV stops there too.
Each exact test keeps your optional workpad and now also remembers completed steps on this device. The Resume Diagnosis page can bring you back to the next incomplete step. Nothing is submitted to FPV.

How the diagnostic system works

  1. Start with the symptom tree, not the tool.
  2. When the tree calls for a measurement, open the linked exact test.
  3. Perform the test under the stated conditions and record the result.
  4. Use PASS or FAIL to return to the correct diagnostic branch.
  5. After any repair, repeat the failed test and then verify the original complaint.
BATTERY

Battery & terminal inspection

Prove the battery and side-terminal connections before starter, charging or draw diagnosis.

FUEL

Fuel-pressure test

55–60 psi commanded-pump test plus one-minute pressure-retention branch.

COOLING

Cooling-system pressure test

Cold-system pressure check with a two-minute hold requirement.

COOLING

Pressure-cap test

Verify rated-pressure hold and release behavior before deeper cooling diagnosis.

COOLING

Thermostat test

Measured opening/closing behavior instead of guessing from symptoms.

COOLING

Cooling-fan function test

Low/high scan-tool commands before relay or motor isolation.

CHARGING

Generator cable voltage-drop test

Loaded positive and ground path checks at 2,500 RPM; 0.5 V maximum per path.

BATTERY DRAW

Parasitic-draw current test

Protected meter insertion, 15-minute sleep period and reserve-capacity-based limit.