Identify the pattern
Note whether every blower speed is dead, only certain speeds fail, or operation is intermittent. Those patterns point to different branches.
A dead blower motor is an electrical symptom. The factory service information provides separate blower-motor testing and HVAC symptom diagnosis, so start at the circuit instead of the motor.
Note whether every blower speed is dead, only certain speeds fail, or operation is intermittent. Those patterns point to different branches.
Use the applicable wiring diagram to verify circuit protection, switch/control output, relay/resistor path where applicable, connector condition and motor power/ground.
Only condemn the blower motor after its required feed and ground are present under the failure condition and the motor still does not operate correctly.
Loss of selected speeds, a bad connection, control fault or power/ground problem can mimic a failed motor.